| Probe 1:1-1:10 - HP-3060 - Specification | |
|---|---|
| Max. input voltage | |
| 1:1 | 300 V CAT I / 150 V CAT II (DC + peak AC), derating with frequency |
| 1:10 | 600 V CAT I / 300 V CAT II (DC + peak AC), derating with frequency |
| Input resistance | |
| 1:1 | 1 MOhm oscilloscope input resistance |
| 1:10 | 10 MOhm when used with oscilloscopes which have 1 MOhm input |
| Input capacitance | |
| 1:1 | 128 pF plus oscilloscope capacitance |
| 1:10 | Approx. 23 pF |
| Bandwidth | |
| 1:1 | DC to 6 MHz |
| 1:10 | DC to 60 MHz |
| Rise time | |
| 1:1 | 58 nsec |
| 1:10 | 5.8 nsec |
| Compensating range | 15 - 35 pF |
| Cable length | 1.4 m (55") |
| Accessories | Channel identifier clip Sprung hook Ground lead Insulating tip IC tip Adjusting tool Measuring tip BNC adapter |