Sub pages

Handyprobe HP2 - Specification

Handyprobe HP2

The Handyprobe HP2 is no longer manufactured and sold.

Acquisition system
Analog input channels1, probe tip
Resolution8 bit = 0.39%
Accuracy1% ± 1 LSB
Ranges0.5 V to 400 V full scale
CouplingAC/DC
Impedance1 MOhm / 30 pF
Protection500 V
Bandwidth (-3dB)DC to 2 MHz maximum
AC coupling cut off frequency (-3 dB)± 1.5 Hz
Maximum sampling rate20 MS/s, 50 ns (model HP2-20MHz)
10 MS/s, 100 ns (model HP2-10MHz)
5 MS/s, 200 ns (model HP2-5MHz)
2 MS/s, 500 ns (model HP2-2MHz)
1 MS/s, 1 µs (model HP2-1MHz)
Sampling clock sourceinternal
Accuracy0.01%
Stability±100 ppm over -40°C to +85°C
Memory65536 samples
Trigger system
Systemdigital, 2 levels
Sourcechannel, keyboard
Trigger modesrising slope, falling slope, inside window, outside window
Level adjustment0 to 100% of full scale
Hysteresis adjustment0 to 100% of full scale
Resolution0.39% (8 bits)
Pre trigger0 to 65535 samples (0 to 100%)
Post trigger0 to 65535 samples (0 to 100%)
Interface
InterfaceLPT
Power Requirements
Power from LPT port200 mA max (1 W max)
Physical
Instrument height22 mm (0.8 inch)
Instrument length125 mm (4.9 inch)
Instrument width43 mm (1.7 inch)
Cord length1.8 m (70 inch)
Weight260 g (9.2 ounce)
I/O connectors
Channel 1 inprobe tip
Channel 1 ground13 cm wire with isolated crocodile clip
parallel portfixed cable with 25 pin male D-Sub connector
System requirements
PC I/O connectionparallel port
Operating systemWindows 95/98/NT4/2000/ME/XP
Certifications and compliences
CE mark complianceYes
Package
InstrumentHandyprobe HP2
SoftwareWindows 95/98/NT4/2000/ME/XP on CD
Manualsinstrument manual and software user's manuals
color printed on paper and digital on CD
Options
Optionally availablebanana sockets instead of probe tip and ground wire