Sub pages

Specification

Janatek LA-Gold-36 - Specification

Add to cart
LA-Gold-36
Acquisition system
Number of input channels32 digital
Voltage range-60 V to +60 V
Impedance1 MOhm / 5 pF
Bandwidth100 MHz min
Threshold voltage-5 V to +5V
4 individual variable thresholds (1 for each group of 8 channels)
Data buffer Size1 Meg samples per channel up to 500 MHz sampling rate
4k samples per channel minimum at 1 GHz sampling rate (dependent on no. of channels used)
Pre/post-trigger bufferData buffer is divided in pre- and post trigger section,
sizes can be set in 1000 samples steps
Internal sampling clock 
Rates1 GHz down to 100 Hz
Stability100 ppm
External sampling clockSynchronized capturing into linear/ring buffer
Linear capture start on trigger or immediately
InputInput to Ch31
More inputs may be defined in later software versions
asynchronousclock on rising/falling edge, 50 MHz max.
synchronousclock on rising/falling edge, 50 MHz max.
data valid 10 ns before clock edge
Digital logger clock 
RatesLog rate: 1 second to 1 hour in 1 second steps
StabilityLogger timing obtained from PC
Extended capture timeVaries depending on the sampling rate;
500 MHz: 33ms max ... 1.25 kHz: 1677s max
Trigger conditions
Pattern"1", "0" and "don?t care" conditions selectable on all channels
EdgeOn any one or combination of channels. Rising edge, falling edge, or change-of-state
Edge/Pattern combinationsEdge and pattern triggering may be combined for single captures or for conditionally continuous capture:
Pattern
Rising Edge
Falling Edge
Change of State
Pattern OR/AND/THEN rising/falling edge/Change of state
Rising edge/falling edge/Change of state OR/AND/THEN pattern
Pattern < duration (glitch capture)
ContinuousUnconditionally: Screen updates at regular intervals
Conditionally: Display updates on detecting a trigger condition
Mouse/KeyboardA trigger may be forced
Pattern Generator
Pattern sourcePattern editor or user file
Nr of channels8
Data to output clock100 MHz max
Start conditionsOn logic analyzer start or arm
trigger condition
Start button
Minimum input impedance of load4k7 / 100pF
Output level+3.3 Volt
Modes of OperationSingle/Continuous
Software
Display 
No. of channelsAny number of channels may be displayed.
Channel/group namesUser specified signal/group names
Grouped channel values may be displayed in Hex, decimal or binary
Display order / ColorsUser specified
ZoomingZoom in/out/previous/all/between cursors
Single captureCaptures a single set of data
Continuous capture displayUnconditionally: Continuously captures and displays data at a fixed update period
Conditionally: Updates the display each time a specified edge or pattern trigger condition is met
CursorsVarious for time measurements, indicating the trigger point, etc.
Time measurementsThe time differences between any two cursor lines or trigger line may be displayed.
Take measurement easily by clicking mouse on first edge and on second edge to get the time difference.
The time difference may also be indicated as a frequency.
Edge snappingCursors (X, Y & Z) snap to signal edges for accurate time measurements
Pattern searchAny channel. Conditions may be specified for 1, 0 and don't care conditions.
Search from start/cursors
repeated search
Saving to diskBinary Data, Hex, Spreadsheet (CSV), configuration
Printed outputThe timing diagrams, bitmaps, binary and hex data, may be printed. Landscape and portrait.
Software Requirements
Operating SystemWindows 2000, XP, Vista32 or later, compatible versions
Interface
USBUSB 2.0 High Speed (480 Mbit/sec)
USB 1.1 Full Speed (12 Mbit/sec) compatible
Power Requirements
Power from USB or external adapter3.6 Watt typical, capturing data without pattern generator
3.8 Watt typical, capturing data with pattern generator
Physical
Instrument height26 mm
Instrument length136 mm
Instrument width122 mm
Operating temperature10 ºC - 40 ºC
Weight260 gram
Package contents
LA-Gold-36 instrument 
Quality SMD test clips with ground lead32
External power supply 
USB cable1.80 m, USB2 high speed
Printed user's manual 
Software and documentation on CDROM 
Handy carry case