The HP-2022 is a passive high impedance oscilloscope probe designed and calibrated for use on
instruments having an input impedance of 1 Mohm shunted by 20 pF.
The modular construction facilitates simple field replacement of the major parts.
Specification
Probe 1:1 - HP-2022 - Specification
Max. input voltage
600V CAT I , 300V CAT II (DC + peak AC), derating with frequency
Input resistance
1 Mohm oscilloscope input resistance
Input capacitance
46 pF plus oscilloscope input capacitance)
Bandwidth
DC to 15 MHz
Rise time
23 ns
Cable length
1.2 m (47")
Accessories
Channel identifier clip Sprung hook Ground lead Insulating tip IC tip Measuring tip BNC adapter