| Acquisition system |
| Number of input channels | 16 digital |
| Voltage range | -60 V to +60 V |
| Impedance | 1 MOhm / 5 pF |
| Bandwidth | 100 MHz |
| Threshold voltage | -5 V to +5V |
| Data buffer Size | 1 Meg samples per channel up to 500 MHz sampling rate 20k samples per channel at 1 GHz sampling rate |
| Pre/post-trigger buffer | Data buffer is divided in pre- and post trigger section, sizes can be set in 1000 samples steps |
| Internal sampling clock | |
| Rates | 1 GHz down to 100 Hz |
| Stability | 100 ppm |
| External sampling clock | Synchronized capture: 50 MHz Max Ring buffer configuration: Operates with pre and post trigger buffer Linear buffer configuration: Start capture immediate or from trigger. |
| Digital logger clock | |
| Rates | Log rate: 1 second to 1 hour in 1 second steps |
| Stability | Logger timing obtained from PC |
| Extended capture time | Varies depending on the sampling rate; 500 MHz: 33ms max ... 1.25 kHz: 1677s max |
| |
| Trigger conditions |
| Pattern | "1", "0" and "don’t care" ("X") conditions selectable on all channels |
| Pattern valid < duration | Glitch Capture. Pattern duration may be specified in steps of 20ns to 1ms. Duration tolerance of ±20ns |
| Pattern valid > duration | Pattern duration may be specified in steps of 20ns to 1ms. Duration tolerance of ±20ns |
| Edge | On any one or combination of channels. Rising edge, falling edge, or change-of-state |
| Edge/Pattern combinations | Edge and pattern triggering may be combined for single captures or for conditionally continuous capture: Pattern Rising Edge Falling Edge Change of State Pattern OR/AND/THEN rising/falling edge/Change of state Rising edge/falling edge/Change of state OR/AND/THEN pattern Pattern < duration (glitch capture) |
| Continuous | Unconditionally: Trigger forced internally and display updates at regular intervals Conditionally: Display updates on detecting a trigger condition |
| Mouse/Keyboard | A trigger may be forced |
| |
| Pattern Generator |
| Nr of channels | 8 |
| Buffer depth | 40 KB |
| Data output clock rate | 50 MHz max |
| Output signal amplitude | 2.5V to 4.8V |
| Minimum input impedance of load | 4k7 / 100pF |
| Start conditions | On logic analyzer start or arm trigger condition Start button |
| Modes of Operation | Single/Continuous |
| Pattern source | Pattern editor or user file |
| |
| Software |
| Display | |
| No. of channels | Any number of channels may be displayed. |
| Channel/group names | User specified signal/group names Grouped channel values may be displayed in Hex, decimal or binary |
| Display order / Colors | User specified |
| Zooming | Zoom in/out/previous/all/between cursors |
| Single capture | Captures a single set of data |
| Continuous capture display | Unconditionally: Continuously captures and displays data at a fixed update period Conditionally: Updates the display each time a specified edge or pattern trigger condition is met |
| Cursors | Various for time measurements, indicating the trigger point, etc. |
| Time measurements | The time differences between any two cursor lines or trigger line may be displayed. Take measurement easily by clicking mouse on first edge and on second edge to get the time difference. The time difference may also be indicated as a frequency. |
| Edge snapping | Cursors (X, Y & Z) snap to signal edges for accurate time measurements |
| Pattern search | Any channel. Conditions may be specified for 1, 0 and don't care conditions. Search from start/cursors repeated search |
| Saving to disk | Binary Data, Hex, Spreadsheet (CSV), configuration |
| Printed output | The timing diagrams, bitmaps, binary and hex data, may be printed. Landscape and portrait. |
| Protocol analysis | UART/RS232 Monitor/generate signals |
| |
| Software Requirements |
| Operating System | Windows 2000, XP, Vista32 or later, compatible versions |
| |
| Interface |
| USB | USB 2.0 High Speed (480 Mbit/sec) USB 1.1 Full Speed (12 Mbit/sec) compatible |
| Power Requirements |
| Power from USB | 2.5 Watt typical, capturing data without pattern generator 3 Watt typical, capturing data with pattern generator |
| |
| Physical |
| Instrument height | 26 mm |
| Instrument length | 162 mm |
| Instrument width | 84 mm |
| Operating temperature | 10 ºC - 40 ºC |
| Weight | 220 gram |
| |
| Package contents |
| LA-Gold-16 instrument | |
| Quality SMD test clips with ground lead | 16 |
| USB cable | 1.80 m, USB2 high speed |
| Printed user's manual | |
| Software and documentation on CDROM | |
| |