| Acquisition system |
| Number of input channels | 32 digital |
| Voltage range | -60 V to +60 V |
| Impedance | 1 MOhm / 5 pF |
| Bandwidth | 100 MHz min |
| Threshold voltage | -5 V to +5V 4 individual variable thresholds (1 for each group of 8 channels) |
| Data buffer Size | 1 Meg samples per channel up to 500 MHz sampling rate 4k samples per channel minimum at 1 GHz sampling rate (dependent on no. of channels used) |
| Pre/post-trigger buffer | Data buffer is divided in pre- and post trigger section, sizes can be set in 1000 samples steps |
| Internal sampling clock | |
| Rates | 1 GHz down to 100 Hz |
| Stability | 100 ppm |
| External sampling clock | Synchronized capturing into linear/ring buffer Linear capture start on trigger or immediately |
| Input | Input to Ch31 More inputs may be defined in later software versions |
| asynchronous | clock on rising/falling edge, 50 MHz max. |
| synchronous | clock on rising/falling edge, 50 MHz max. |
| | data valid 10 ns before clock edge |
| Digital logger clock | |
| Rates | Log rate: 1 second to 1 hour in 1 second steps |
| Stability | Logger timing obtained from PC |
| Extended capture time | Varies depending on the sampling rate; 500 MHz: 33ms max ... 1.25 kHz: 1677s max |
| |
| Trigger conditions |
| Pattern | "1", "0" and "don’t care" conditions selectable on all channels |
| Edge | On any one or combination of channels. Rising edge, falling edge, or change-of-state |
| Edge/Pattern combinations | Edge and pattern triggering may be combined for single captures or for conditionally continuous capture: Pattern Rising Edge Falling Edge Change of State Pattern OR/AND/THEN rising/falling edge/Change of state Rising edge/falling edge/Change of state OR/AND/THEN pattern Pattern < duration (glitch capture) |
| Continuous | Unconditionally: Screen updates at regular intervals Conditionally: Display updates on detecting a trigger condition |
| Mouse/Keyboard | A trigger may be forced |
| |
| Pattern Generator |
| Pattern source | Pattern editor or user file |
| Nr of channels | 8 |
| Data to output clock | 100 MHz max |
| Start conditions | On logic analyzer start or arm trigger condition Start button |
| Minimum input impedance of load | 4k7 / 100pF |
| Output level | +3.3 Volt |
| Modes of Operation | Single/Continuous |
| |
| Software |
| Display | |
| No. of channels | Any number of channels may be displayed. |
| Channel/group names | User specified signal/group names Grouped channel values may be displayed in Hex, decimal or binary |
| Display order / Colors | User specified |
| Zooming | Zoom in/out/previous/all/between cursors |
| Single capture | Captures a single set of data |
| Continuous capture display | Unconditionally: Continuously captures and displays data at a fixed update period Conditionally: Updates the display each time a specified edge or pattern trigger condition is met |
| Cursors | Various for time measurements, indicating the trigger point, etc. |
| Time measurements | The time differences between any two cursor lines or trigger line may be displayed. Take measurement easily by clicking mouse on first edge and on second edge to get the time difference. The time difference may also be indicated as a frequency. |
| Edge snapping | Cursors (X, Y & Z) snap to signal edges for accurate time measurements |
| Pattern search | Any channel. Conditions may be specified for 1, 0 and don't care conditions. Search from start/cursors repeated search |
| Saving to disk | Binary Data, Hex, Spreadsheet (CSV), configuration |
| Printed output | The timing diagrams, bitmaps, binary and hex data, may be printed. Landscape and portrait. |
| |
| Software Requirements |
| Operating System | Windows 98, ME, 2000, XP or later, compatible versions |
| |
| Interface |
| USB | USB 2.0 High Speed (480 Mbit/sec) USB 1.1 Full Speed (12 Mbit/sec) compatible |
| Power Requirements |
| Power from USB or external adapter | 3.6 Watt typical, capturing data without pattern generator 3.8 Watt typical, capturing data with pattern generator |
| |
| Physical |
| Instrument height | 26 mm |
| Instrument length | 136 mm |
| Instrument width | 122 mm |
| Operating temperature | 10 ºC - 40 ºC |
| Weight | 260 gram |
| |
| Package contents |
| LA-Gold-36 instrument | |
| Quality SMD test clips with ground lead | 32 |
| External power supply | |
| USB cable | 1.80 m, USB2 high speed |
| Printed user's manual | |
| Software and documentation on CDROM | |